Heat pumps · Error codes · Kingspan
14Kingspan · Aeromax Plus air-to-water monobloc (KHP0038-KHP0042)

14 on a Kingspan Aeromax Plus air-to-water monobloc: Loss of signal from inverter board / high temperature release (thermostat on compressor)

Short answer

On a Kingspan heat pump, 14 means: Loss of signal from inverter board / high temperature release (thermostat on compressor). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Loss of signal from inverter board / high temperature release (thermostat on compressor).

Part involved: Inverter board link / compressor top thermostat.

Likely causes:

  • Compressor overheating tripping compressor thermostat (opens >120 C, resets <90 C).
  • Inverter board communication loss.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Manual: after the error has been cleared, reset by turning off the mains supply for 10 seconds and on again.

What you can check

  • Note the code/LED pattern and the model from the rating plate, then contact a heat pump/refrigeration engineer.
  • Check the heat pump's breaker/isolator at the consumer unit is on.
  • Check the outdoor unit is not blocked by leaves, snow or debris.

What the engineer will check

  • Check compressor thermostat, inverter board, refrigerant charge (overheating can indicate low charge).

Who to ask for: refrigeration / heat pump engineer.

Certification: F-gas certification (refrigerant circuit work) and electrical competence.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026