FLH1 on a Kensa heat pump: Heating-mode load temperature differential T2-T1 greater than the low-flow differential

Short answer

On a Kensa heat pump, FLH1 means: Heating-mode load temperature differential T2-T1 greater than the low-flow differential. The heat pump keeps running.

Reviewed 23 September 2026 · 4 sources

What it means

The manual says: Heating-mode load temperature differential T2-T1 greater than the low-flow differential.

Part involved: Load pump / distribution flow.

When it shows: Error level per manual: Warning.

Likely causes:

  • Low load pump speed, low load flow, restrictions in heating distribution (closed valves/actuators, air), incorrect low-flow differential setting.

Is it safe?

Does the heat pump stop?No
SeverityWarning

The heat pump keeps running.

Resetting itself: n/a (warning).

Manual reset: unknown.

What you can check

  • Note the code shown on the controller/LED; check the heat pump isolator and consumer-unit breaker are on; check thermostat/timer settings.

What the engineer will check

  • Follow Kensa fault table actions: Low load pump speed, low load flow, restrictions in heating distribution (closed valves/actuators, air), incorrect low-flow differential setting.

Who to ask for: Heating engineer / GSHP installer.

Certification: MCS-certified GSHP installer recommended; Kensa-trained.