Heat pumps · Error codes · Kensa
DI5Kensa

DI5 on a Kensa heat pump: High pressure switch open circuit

Short answer

On a Kensa heat pump, DI5 means: High pressure switch open circuit. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 3 sources

What it means

The manual says: High pressure switch open circuit.

Part involved: High-pressure switch (compressor 1).

When it shows: Error level per manual: Fault.

Likely causes:

  • Load-side flow restriction (often with FLH1/FLC1), load pump failure, T1 probe failure (E1).

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the code shown on the controller/LED; check the heat pump isolator and consumer-unit breaker are on; check thermostat/timer settings.

What the engineer will check

  • Follow Kensa fault table actions: Load-side flow restriction (often with FLH1/FLC1), load pump failure, T1 probe failure (E1).

Who to ask for: Refrigeration engineer (F-gas certified) / Kensa technical support.

Certification: F-gas Category I (refrigerant circuit work); MCS-certified GSHP installer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.