EE on a Hisense Hi-Therma Monobloc: Compressor Protection Alarm (It can not be reset from Master Controller)

Short answer

On a Hisense heat pump, EE means: Compressor Protection Alarm (It can not be reset from Master Controller). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Compressor Protection Alarm (It can not be reset from Master Controller).

Part involved: compressor, inverter/driver PCB, power supply.

When it shows: This alarm code appears when alarms 02, 07, 08, 43 to 45, 47 occur three times within 6 hours.

Likely causes:

  • This alarm code appears when alarms 02, 07, 08, 43 to 45, 47 occur three times within 6 hours.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Remove the cause; EE cannot be reset from the master controller.

What you can check

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • If the breaker or RCD trips repeatedly, leave the heat pump switched off and call an engineer; do not keep resetting it.

What the engineer will check

  • Follow the handbook alarm-code flowchart (O.U. section from printed p.335, I.U. section from viewer p.383).
  • Check supply voltage and phase balance.
  • Check compressor windings and inverter/driver PCB per flowchart.
  • Check heat-sink cooling and connections.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026