SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Heliotherm
LOW-PRESSUREHeliotherm · Basic Comfort air split (HP..L-K-BC / HP..L-M-BC)

LOW-PRESSURE on a Heliotherm Basic Comfort air split: Evaporation pressure below safety-chain limit

Short answer

On a Heliotherm heat pump, LOW-PRESSURE means: Evaporation pressure below safety-chain limit. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Evaporation pressure below safety-chain limit.

Part involved: Low pressure (evaporating pressure).

Likely causes:

  • Defective fan.
  • Refrigerant deficiency/leak.
  • Moisture in circuit - expansion valve frozen.
  • Rotalock valve fully opened during commissioning.
  • Foreign gas in refrigerant circuit.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: Fault clearance function in the controller main menu (web control 321 manual p.27, intended for the Heliotherm competence partner).

What you can check

  • Note the error text shown on the controller and contact your Heliotherm competence partner (manual: the heat pump should be shut off and checked by a trained specialist).
  • Check the outdoor evaporator is not blocked by leaves, snow or debris.

What the engineer will check

  • Inspect outdoor evaporator wiring.
  • Leak-test and recharge per chapter 13.
  • Check sight glass for moisture.
  • Close Rotalock valve.
  • Replace refrigerant if contaminated.

Who to ask for: heat pump / refrigeration (Heliotherm competence partner).

Certification: F-gas certification for refrigerant work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026