DISCHARGE-MAXHeliotherm · Basic Comfort air split (HP..L-K-BC / HP..L-M-BC)

DISCHARGE-MAX on a Heliotherm Basic Comfort air split: Discharge (hot gas) maximum temperature limit exceeded

Short answer

On a Heliotherm heat pump, DISCHARGE-MAX means: Discharge (hot gas) maximum temperature limit exceeded. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Discharge (hot gas) maximum temperature limit exceeded.

Part involved: Discharge MAX error.

Likely causes:

  • Refrigerant deficiency/leak.
  • Control settings cause refrigerant circuit oscillation.
  • Sensor defective.
  • Control output X16 HGT defective.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: Fault clearance function in the controller main menu (web control 321 manual p.27, intended for the Heliotherm competence partner).

What you can check

  • Note the error text shown on the controller and contact your Heliotherm competence partner (manual: the heat pump should be shut off and checked by a trained specialist).
  • Check the outdoor evaporator is not blocked by leaves, snow or debris.

What the engineer will check

  • Leak-check and recharge.
  • Check dsi settings.
  • Check/replace discharge sensor.
  • Check control input/output X16; replace controller if needed.

Who to ask for: heat pump / refrigeration (Heliotherm competence partner).

Certification: F-gas certification for refrigerant work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026