LF on a Gree heat pump: Sensing circuit error or current sensor error

Short answer

On a Gree heat pump, LF means: Sensing circuit error or current sensor error. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Versati III Monobloc (R32)

The manual says: Sensing circuit error or current sensor error.

Part involved: temperature/pressure sensor.

On the Versati III Split / All-in-one (R32)

The manual says: Overspeed.

On the Versati IV Split / All-in-one (R32)

The manual says: Overspeed.

Is it safe?

On the Versati III Monobloc (R32)

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: unknown.

On the Versati III Split / All-in-one (R32)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Versati IV Split / All-in-one (R32)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

What you can check

On the Versati III Monobloc (R32)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the controller display is lit; a single power cycle at the isolator may be tried only if your installer or manual allows it.

On the Versati III Split / All-in-one (R32)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.

On the Versati IV Split / All-in-one (R32)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.

What the engineer will check

On the Versati III Monobloc (R32)

  • Follow the Gree troubleshooting flowchart for this code in the service manual.
  • Check sensor connector and wiring.
  • Measure sensor resistance against the manual's sensor table.
  • Replace sensor or PCB as indicated by the troubleshooting flowchart.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

On the Versati III Split / All-in-one (R32)

  • Follow the Gree troubleshooting flowchart for this code in the service manual.
  • Follow the manufacturer's troubleshooting flowchart for this code.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

On the Versati IV Split / All-in-one (R32)

  • Follow the Gree troubleshooting flowchart for this code in the service manual.
  • Follow the manufacturer's troubleshooting flowchart for this code.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026