E3 on a Gree heat pump: Low pressure protection

Short answer

On a Gree heat pump, E3 means: Low pressure protection. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 6 sources

What it means

On the Versati II (R410A)

The manual says: Low pressure protection.

Part involved: compressor, pressure switches, expansion valve, refrigerant charge.

Likely causes:

  • Comp Low-pressure switch is broken or the wiring is loose.
  • The system has leaked.
  • The fans stop running or reverse.

On the Versati III Monobloc (R32)

The manual says: Low pressure protection.

Part involved: compressor, pressure switches, expansion valve, refrigerant charge.

On the Versati III Split / All-in-one (R32)

The manual says: Low pressure protection.

Part involved: compressor, pressure switches, expansion valve, refrigerant charge.

On the Versati IV Monobloc (R32)

The manual says: Comp Low- pressure protection.

Part involved: compressor, pressure switches, expansion valve, refrigerant charge.

Likely causes:

  • Comp Low-pressure switch is broken or the wiring is loose.
  • The system has leaked.
  • The fans stop running or reverse.

On the Versati IV Split / All-in-one (R32)

The manual says: Low pressure protection.

Part involved: compressor, pressure switches, expansion valve, refrigerant charge.

Likely causes:

  • Low-pressure switch broken or wiring loose.
  • Fans stopped or running in reverse.
  • Refrigerant leak.

On the Versati V R290 Monobloc

The manual says: Low pressure protection.

Part involved: compressor, pressure switches, expansion valve, refrigerant charge.

Is it safe?

On the Versati II (R410A)

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: If it occurs for 2 times during 40 minu tes, it is cleared by de-energization or turnning off. If it occurs for less than 2 times, it will be automatically cleared.

On the Versati III Monobloc (R32)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

On the Versati III Split / All-in-one (R32)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

On the Versati IV Monobloc (R32)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: It will be cleared if the malfunction is removed after the unit has been turned off.

On the Versati IV Split / All-in-one (R32)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

On the Versati V R290 Monobloc

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

What you can check

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the outdoor unit is not blocked by leaves, debris, snow or ice and that nothing is stored against the grilles.

What the engineer will check

  • Follow the Gree troubleshooting flowchart for this code in the service manual.
  • Check refrigerant pressures and charge (F-gas / flammable refrigerant competent person only).
  • Check expansion valve, pressure switches/sensors and discharge temperature.
  • Check outdoor coil airflow and blockages.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026