Heat pumps · Error codes · Gree
C5Gree

C5 on a Gree heat pump: Indoor capacity switch error

Short answer

On a Gree heat pump, C5 means: Indoor capacity switch error. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 6 sources

What it means

On the Versati II (R410A)

The manual says: Indoor capacity switch error.

On the Versati III Monobloc (R32)

The manual says: Incorrect capacity DIP switch setting.

Part involved: PCB / communication wiring / settings.

On the Versati III Split / All-in-one (R32)

The manual says: Capacity DIP switch error / Jumper cap error.

Part involved: PCB / communication wiring / settings.

On the Versati IV Monobloc (R32)

The manual says: Cpacity switch error.

Likely causes:

  • The jumper trips off.

On the Versati IV Split / All-in-one (R32)

The manual says: Capacity DIP switch error / Jumper cap error.

Part involved: PCB / communication wiring / settings.

On the Versati V R290 Monobloc

The manual says: Capacity DIP switch error / Jumper cap error.

Part involved: PCB / communication wiring / settings.

Is it safe?

On the Versati II (R410A)

Does the heat pump stop?Not stated
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: no.

Manual reset: De-energize the unit and then, energize it again. If the malfunction is removed, the code will be cleared.

On the Versati III Monobloc (R32)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Versati III Split / All-in-one (R32)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Versati IV Monobloc (R32)

Does the heat pump stop?Not stated
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: no.

Manual reset: De-energize the unit and then energize it again. If the malfunction is removed, the code will be cleared.

On the Versati IV Split / All-in-one (R32)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Versati V R290 Monobloc

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

What you can check

On the Versati II (R410A)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.

On the Versati III Monobloc (R32)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the controller display is lit; a single power cycle at the isolator may be tried only if your installer or manual allows it.
  • Check controller mode/temperature/timer settings have not been changed; setup (DIP switch) errors need the installer.

On the Versati III Split / All-in-one (R32)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the controller display is lit; a single power cycle at the isolator may be tried only if your installer or manual allows it.
  • Check controller mode/temperature/timer settings have not been changed; setup (DIP switch) errors need the installer.

On the Versati IV Monobloc (R32)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.

On the Versati IV Split / All-in-one (R32)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the controller display is lit; a single power cycle at the isolator may be tried only if your installer or manual allows it.
  • Check controller mode/temperature/timer settings have not been changed; setup (DIP switch) errors need the installer.

On the Versati V R290 Monobloc

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the controller display is lit; a single power cycle at the isolator may be tried only if your installer or manual allows it.
  • Check controller mode/temperature/timer settings have not been changed; setup (DIP switch) errors need the installer.

What the engineer will check

  • Follow the Gree troubleshooting flowchart for this code in the service manual.
  • Check the capacity jumper / DIP setting on the main board against the model.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026