F2 on a Gree heat pump: Solar kit-water flow switch

Short answer

On a Gree heat pump, F2 means: Solar kit-water flow switch. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the Versati III Monobloc (R32)

The manual says: Solar kit-water flow switch.

Part involved: water flow switch, circulation pump, water temperature.

On the Versati III Split / All-in-one (R32)

The manual says: Economizer inlet temperature sensor.

Part involved: temperature/pressure sensor.

On the Versati IV Split / All-in-one (R32)

The manual says: Economizer inlet temperature sensor.

Part involved: temperature/pressure sensor.

On the Versati V R290 Monobloc

The manual says: Economizer inlet temperature sensor.

Part involved: temperature/pressure sensor.

Is it safe?

On the Versati III Monobloc (R32)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Versati III Split / All-in-one (R32)

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: unknown.

On the Versati IV Split / All-in-one (R32)

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: unknown.

On the Versati V R290 Monobloc

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: unknown.

What you can check

On the Versati III Monobloc (R32)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the heating system pressure gauge shows the pressure your installer set (typically about 1-2 bar); if it is low, report it rather than refilling unless you have been shown how. Check any filling loop is closed.
  • Check radiator valves / underfloor zones are open and thermostats are calling for heat.
  • In freezing weather keep the heat pump powered on (its frost protection relies on power) and check the outdoor unit is clear of snow/ice.

On the Versati III Split / All-in-one (R32)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the controller display is lit; a single power cycle at the isolator may be tried only if your installer or manual allows it.

On the Versati IV Split / All-in-one (R32)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the controller display is lit; a single power cycle at the isolator may be tried only if your installer or manual allows it.

On the Versati V R290 Monobloc

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the controller display is lit; a single power cycle at the isolator may be tried only if your installer or manual allows it.

What the engineer will check

On the Versati III Monobloc (R32)

  • Follow the Gree troubleshooting flowchart for this code in the service manual.
  • Check water pressure, strainer/filter and air in the system.
  • Check circulation pump operation and flow sensor/switch.
  • Check heater safety thermostats and wiring.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

On the Versati III Split / All-in-one (R32)

  • Follow the Gree troubleshooting flowchart for this code in the service manual.
  • Check sensor connector and wiring.
  • Measure sensor resistance against the manual's sensor table.
  • Replace sensor or PCB as indicated by the troubleshooting flowchart.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

On the Versati IV Split / All-in-one (R32)

  • Follow the Gree troubleshooting flowchart for this code in the service manual.
  • Check sensor connector and wiring.
  • Measure sensor resistance against the manual's sensor table.
  • Replace sensor or PCB as indicated by the troubleshooting flowchart.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

On the Versati V R290 Monobloc

  • Follow the Gree troubleshooting flowchart for this code in the service manual.
  • Check sensor connector and wiring.
  • Measure sensor resistance against the manual's sensor table.
  • Replace sensor or PCB as indicated by the troubleshooting flowchart.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.