F.823Glow-worm · GeniaAir (HA x-7.1 O)

F.823 on a Glow-worm GeniaAir: Compressor temperature switch has triggered

Short answer

On a Glow-worm heat pump, F.823 means: Compressor temperature switch has triggered. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Compressor temperature switch has triggered.

Part involved: Compressor temperature switch has triggered.

Likely causes:

  • The hot gas thermostat shuts down the heat pump if the temperature in the refrigerant circuit is too high. Following a waiting period, the heat pump attempts to start once more. After three failed start attempts in succession, a fault message is displayed. Max. refrigerant circuit temperature: 130 °C. Waiting period: 5 mins (after it first occurs). Waiting period: 30 mins (after it occurs a second time and any other time after that). The fault counter is reset if both of the following conditions are met: Heat demand without switching off prematurely. 60 mins uninterrupted operation.
  • Glow-worm trade page: Compressor temperature switch has triggered Electronic expansion valve (EEV) fault, fault in the electrical connection to the EEV, contamination in the refrigerant circuit i.e. dirt or moisture.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no - the fault remains displayed until the cause is eliminated.

Manual reset: yes - after the cause is eliminated, press the reset button (indoor unit) or reset via the system control; if it recurs after several resets contact customer service.

What you can check

  • Note the full code and text shown on the display (and the date/time it appeared). Check the outdoor unit's air inlet and outlet are not blocked by leaves, debris, snow or ice build-up and clear any loose debris from around it (do not open the casing, poke the fins or use tools). Glow-worm's MiPro Sense operating instructions say always contact your competent person in the event of a fault message; until they arrive you may select a limp-home (back-up heater) setting on the control, which is expensive to run. If you smell gas/solvent near the outdoor unit or hear hissing, switch the heat pump off at the isolator, keep ignition sources away and call an engineer.

What the engineer will check

  • Check the EEV. 2. Replace the dirt filter in the refrigerant circuit, if required.

Who to ask for: F-gas certified refrigeration engineer with heat pump experience (R290 flammable-refrigerant competence required for aroTHERM plus / GeniaAir).

Certification: F-gas Category I (Regulation (EU) 517/2014 as retained in GB) certificate; flammable (R290) refrigerant training for R290 units.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026