F.718 on a Glow-worm GeniaAir: Environment circuit fan 1 is blocked

Short answer

On a Glow-worm heat pump, F.718 means: Environment circuit fan 1 is blocked. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Environment circuit fan 1 is blocked.

Part involved: Environment circuit fan 1 is blocked.

Likely causes:

  • Fan does not rotate.
  • Glow-worm trade page: Fan unit blocked (fan 1 in the case of a twin fan heat pump) Damage or blockage to fan blade, faulty fan motor, fault in the electrical connection to the fan motor, HMU fault, installer board fault.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no - the fault remains displayed until the cause is eliminated.

Manual reset: yes - after the cause is eliminated, press the reset button (indoor unit) or reset via the system control; if it recurs after several resets contact customer service.

What you can check

  • Note the full code and text shown on the display (and the date/time it appeared). Check the outdoor unit's air inlet and outlet are not blocked by leaves, debris, snow or ice build-up and clear any loose debris from around it (do not open the casing, poke the fins or use tools). Glow-worm's MiPro Sense operating instructions say always contact your competent person in the event of a fault message; until they arrive you may select a limp-home (back-up heater) setting on the control, which is expensive to run.

What the engineer will check

  • Check: Air route (blockage), F1 fuse on the PCB in the fan unit (OMU.

Who to ask for: Vaillant-trained heat pump installer/engineer (MCS-certified installer).

Certification: MCS installer certification; Vaillant product training recommended.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026