Heat pumps · Error codes · Glow-worm
F.703Glow-worm · GeniaAir (HA x-7.1 O)

F.703 on a Glow-worm GeniaAir: Refrigerant circuit low-pressure sensor signal invalid

Short answer

On a Glow-worm heat pump, F.703 means: Refrigerant circuit low-pressure sensor signal invalid. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Refrigerant circuit low-pressure sensor signal invalid.

Part involved: Refrigerant circuit low-pressure sensor signal invalid.

Likely causes:

  • Low-pressure sensor not connected or sensor input has short-circuited.
  • Glow-worm trade page: Low refrigerant pressure sensor fault Refrigerant levels too low Incondensable particles in the refrigerant circuit, electronic expansion valve fault, fault in the electrical connection of the Low-pressure sensor, low-pressure sensor fault.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no - the fault remains displayed until the cause is eliminated.

Manual reset: yes - after the cause is eliminated, press the reset button (indoor unit) or reset via the system control; if it recurs after several resets contact customer service.

What you can check

  • Note the full code and text shown on the display (and the date/time it appeared). Glow-worm's MiPro Sense operating instructions say always contact your competent person in the event of a fault message; until they arrive you may select a limp-home (back-up heater) setting on the control, which is expensive to run.

What the engineer will check

  • Check: Low-pressure sensor (resistance measurement based on sensor characteristic values), wiring harness.

Who to ask for: Vaillant-trained heat pump installer/engineer (MCS-certified installer).

Certification: MCS installer certification; Vaillant product training recommended.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026