F.1117 on a Glow-worm GeniaAir: Frequency inverter phase failure

Short answer

On a Glow-worm heat pump, F.1117 means: Frequency inverter phase failure. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Frequency inverter phase failure.

Part involved: Frequency inverter phase failure.

Likely causes:

  • Defective fuse. Incorrect electrical connections. Mains voltage too low. Compressor/low-tariff power supply not connected. Energy supply company lockout longer than three hours.
  • Glow-worm trade page: Invertor phase failure Incoming main voltage is not within permissible tolerances, electrical phases incorrect (400V versions only), reverse polarity, poor earthing, unstable power supply.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no - the fault remains displayed until the cause is eliminated.

Manual reset: yes - after the cause is eliminated, press the reset button (indoor unit) or reset via the system control; if it recurs after several resets contact customer service.

What you can check

  • Note the full code and text shown on the display (and the date/time it appeared). Check the heat pump supply breaker/isolator (and back-up heater breaker, if separate) at the consumer unit is on; if a breaker has tripped more than once, leave it off and call an engineer - do not open any casing. Glow-worm's MiPro Sense operating instructions say always contact your competent person in the event of a fault message; until they arrive you may select a limp-home (back-up heater) setting on the control, which is expensive to run.

What the engineer will check

  • Check the fuse. 2. Check the electrical connections. 3. Check the voltage at the heat pump electrical connection. 4. Reduce energy supply company anti-cycling time to under three hours.

Who to ask for: Heat pump engineer with electrical competence (qualified electrician for supply/phase faults).

Certification: Competent electrician (BS 7671 / Part P) for supply-side work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.