E931 on an Advantix S.p.A heat pump: Internal communication error

Short answer

On an Advantix S.p.A heat pump, E931 means: Internal communication error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 24 September 2026 · 4 sources

What it means

On the MAXA i-290 (Gamma i-290)

The manual says: Internal communication error.

Part involved: controller / PCB communication.

On the MAXA i-32V5

The manual says: Comunication error with main controller.

Part involved: see manual.

On the MAXA i-32V5 MIDI (i-32V5H Midi)

The manual says: Internal communication error.

Part involved: controller / PCB communication.

On the MAXA i-HPV5H

The manual says: Internal commhunication error.

Part involved: see manual.

Is it safe?

On the MAXA i-290 (Gamma i-290)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

On the MAXA i-32V5

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the MAXA i-32V5 MIDI (i-32V5H Midi)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

On the MAXA i-HPV5H

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

What you can check

  • Note the code shown on the controller and the model number on the unit's rating label before contacting your installer.
  • Check that the heat pump's isolator and consumer-unit breaker are on; do not open any casing.

What the engineer will check

On the MAXA i-290 (Gamma i-290)

  • Check communication cables and connectors between boards/controller.
  • Check board power supplies.
  • Check addressing and firmware compatibility.
  • Replace the faulty board.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas and flammable-refrigerant (R32/R290) handling competence for any refrigerant-circuit work.

On the MAXA i-32V5

  • Follow the manufacturer's troubleshooting for this code.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas and flammable-refrigerant (R32/R290) handling competence for any refrigerant-circuit work.

On the MAXA i-32V5 MIDI (i-32V5H Midi)

  • Check communication cables and connectors between boards/controller.
  • Check board power supplies.
  • Check addressing and firmware compatibility.
  • Replace the faulty board.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas and flammable-refrigerant (R32/R290) handling competence for any refrigerant-circuit work.

On the MAXA i-HPV5H

  • Follow the manufacturer's troubleshooting for this code.

Who to ask for: Heat pump engineer.