E041 on an Advantix S.p.A heat pump: Incongruent temperature alarm

Short answer

On an Advantix S.p.A heat pump, E041 means: Incongruent temperature alarm. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 24 September 2026 · 4 sources

What it means

On the MAXA i-290 (Gamma i-290)

The manual says: Incongruent temperature alarm.

Part involved: compressor / refrigerant circuit.

When it shows: After ~180 s: in heating/DHW, delivery water temperature lower than return -1 C (reversing-valve malfunction); opposite in cooling.

On the MAXA i-32V5

The manual says: Inconsistent temperatures alarm.

Part involved: compressor / refrigerant circuit.

When it shows: After ~180 s: in heating/DHW, delivery water temperature lower than return -1 C (reversing-valve malfunction); opposite in cooling.

On the MAXA i-32V5 MIDI (i-32V5H Midi)

The manual says: Incongruent temperature alarm.

Part involved: compressor / refrigerant circuit.

When it shows: After ~180 s: in heating/DHW, delivery water temperature lower than return -1 C (reversing-valve malfunction); opposite in cooling.

On the MAXA i-HPV5H

The manual says: Incongruent temperature alarm.

Part involved: compressor / refrigerant circuit.

When it shows: After ~180 s: in heating/DHW, delivery water temperature lower than return -1 C (reversing-valve malfunction); opposite in cooling.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: manual reset.

What you can check

  • Note the code shown on the controller and the model number on the unit's rating label before contacting your installer.
  • Check that the heat pump's isolator and consumer-unit breaker are on; do not open any casing.

What the engineer will check

  • Record high/low pressures, discharge/suction temperatures and EEV steps with the unit running.
  • Check water-side flow and air-side coil (blocked/frosted fins).
  • Check pressure switches/transducers and wiring.
  • Leak-test the refrigerant circuit and correct the charge (F-gas / flammable-refrigerant competent engineer only).

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas and flammable-refrigerant (R32/R290) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026