SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Worcester Bosch
UFWorcester Bosch · Greenstar Plus Hybrid (air to water heat pump + Worcester boiler)

UF on a Worcester Bosch Greenstar Plus Hybrid: Safety device to protect against compressor overcurrent: compressor blocked

Short answer

On a Worcester Bosch heat pump, UF means: Safety device to protect against compressor overcurrent: compressor blocked. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Safety device to protect against compressor overcurrent: compressor blocked.

Part involved: external unit PCB / refrigerant circuit.

When it shows: Safety device to protect against compressor overcurrent: compressor blocked.

Likely causes:

  • Overcurrent within 30 s of compressor start: shut-off valves closed; low supply voltage; wiring/plug/phase fault; compressor faulty; power board faulty; DIP switches wrong.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Codes read via outdoor unit LEDs or service tool 7-716-161-051; SW1-2 DIP switch cancels fault displays (engineer).

What you can check

  • Read and note the full FW200/hybrid manager fault code shown on the controller and pass it to your installer.
  • Check the heat pump isolator and consumer-unit breaker(s) are switched on; if a breaker has tripped more than once, leave it off and call an engineer.
  • Check the outdoor unit is not blocked by leaves, snow, ice or other debris (do not open the casing).

What the engineer will check

  • Overcurrent within 30 s of compressor start: shut-off valves closed; low supply voltage; wiring/plug/phase fault; compressor faulty; power board faulty; DIP switches wrong.

Who to ask for: F-gas refrigeration engineer / heat pump installer.

Certification: F-gas certification (Category I) required for refrigerant circuit work; qualified electrician for electrical work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026