U8 on a Worcester Bosch Greenstar Plus Hybrid: Speed fault at the fan motor

Short answer

On a Worcester Bosch heat pump, U8 means: Speed fault at the fan motor. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Speed fault at the fan motor.

Part involved: external unit PCB / refrigerant circuit.

When it shows: Speed fault at the fan motor.

Likely causes:

  • Fan speed <=100 rpm for 15 s at >=20 C outside, or <50 / >1500 rpm for 1 min: faulty fan motor or PCB.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Codes read via outdoor unit LEDs or service tool 7-716-161-051; SW1-2 DIP switch cancels fault displays (engineer).

What you can check

  • Read and note the full FW200/hybrid manager fault code shown on the controller and pass it to your installer.
  • Check the heat pump isolator and consumer-unit breaker(s) are switched on; if a breaker has tripped more than once, leave it off and call an engineer.
  • Check the outdoor unit is not blocked by leaves, snow, ice or other debris (do not open the casing).

What the engineer will check

  • Fan speed <=100 rpm for 15 s at >=20 C outside, or <50 / >1500 rpm for 1 min: faulty fan motor or PCB.

Who to ask for: F-gas refrigeration engineer / heat pump installer.

Certification: F-gas certification (Category I) required for refrigerant circuit work; qualified electrician for electrical work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.