SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Worcester Bosch
U7Worcester Bosch · Greenstar Plus Hybrid (air to water heat pump + Worcester boiler)

U7 on a Worcester Bosch Greenstar Plus Hybrid: Superheating not possible through hot gas temperature being too low

Short answer

On a Worcester Bosch heat pump, U7 means: Superheating not possible through hot gas temperature being too low. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Superheating not possible through hot gas temperature being too low.

Part involved: external unit PCB / refrigerant circuit.

When it shows: Superheating not possible through hot gas temperature being too low.

Likely causes:

  • Superheat -15 C >3 min with LEV almost closed, 10 min after start: loose TH4 connections or fixing; LEV drive/cable contacts; faulty LEV.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Codes read via outdoor unit LEDs or service tool 7-716-161-051; SW1-2 DIP switch cancels fault displays (engineer).

What you can check

  • Read and note the full FW200/hybrid manager fault code shown on the controller and pass it to your installer.
  • Check the heat pump isolator and consumer-unit breaker(s) are switched on; if a breaker has tripped more than once, leave it off and call an engineer.
  • Check the outdoor unit is not blocked by leaves, snow, ice or other debris (do not open the casing).

What the engineer will check

  • Superheat -15 C >3 min with LEV almost closed, 10 min after start: loose TH4 connections or fixing; LEV drive/cable contacts; faulty LEV.

Who to ask for: F-gas refrigeration engineer / heat pump installer.

Certification: F-gas certification (Category I) required for refrigerant circuit work; qualified electrician for electrical work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026