softstarterWorcester Bosch · Greenstore LECP ground source heat pump (System & Combi)

softstarter on a Worcester Bosch Greenstore LECP ground source heat pump: Soft starter alarm (red LED flashes 2/3/4/5)

Short answer

On a Worcester Bosch heat pump, softstarter means: Soft starter alarm (red LED flashes 2/3/4/5). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Soft starter alarm (red LED flashes 2/3/4/5).

Part involved: soft starter.

When it shows: 2 flashes undervoltage <190 VAC (auto reset 5 min); 3 overcurrent during start-up >80 A for 1 s (auto reset); 4 relay protection (user action/possible replacement); 5 incomplete ramp (auto reset). Type 3 indicates compressor fault.

Likely causes:

  • 2 flashes undervoltage <190 VAC (auto reset 5 min); 3 overcurrent during start-up >80 A for 1 s (auto reset); 4 relay protection (user action/possible replacement); 5 incomplete ramp (auto reset). Type 3 indicates compressor fault.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Auto reset with 5 min recovery (2,3,5); unit replacement if 4/5 repeat.

What you can check

  • Read and note the full alarm text and category letter shown on the controller and pass it to your installer.
  • Check the heat pump isolator and consumer-unit breaker(s) are switched on; if a breaker has tripped more than once, leave it off and call an engineer.

What the engineer will check

  • Diagnose per chapter 21: 2 flashes undervoltage <190 VAC (auto reset 5 min); 3 overcurrent during start-up >80 A for 1 s (auto reset); 4 relay protection (user action/possible replacement); 5 incomplete ramp (auto reset). Type 3 indicates compressor fault.

Who to ask for: heat pump installer / electrician.

Certification: Electrical work to BS 7671 by competent person.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026