Max-flow-temperature-heating-systemWorcester Bosch · Greensource Split HP Hydrolight / Hydrocomfort

Max-flow-temperature-heating-system on a Worcester Bosch Greensource Split HP Hydrolight / Hydrocomfort: Alarm: Max flow temperature, heating system

Short answer

On a Worcester Bosch heat pump, Max-flow-temperature-heating-system means: Alarm: Max flow temperature, heating system. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Alarm: Max flow temperature, heating system.

Part involved: E11.T1 flow sensor.

When it shows: Flow exceeds E11.T1 set point maximum + 6 K (UFH protection): set point wrong; flow rate fault; external booster anticipated temperature above max flow.

Likely causes:

  • Flow exceeds E11.T1 set point maximum + 6 K (UFH protection): set point wrong; flow rate fault; external booster anticipated temperature above max flow.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Acknowledge by pressing the rotary selector (Acknowledge) on the Hydrolight/Hydrocomfort user interface.

What you can check

  • Read and note the full alarm text shown on the controller and pass it to your installer.
  • Acknowledge the alarm once on the control panel; if it returns, call the installer.

What the engineer will check

  • Check E11.T1 setting, filter, TRVs, external booster settings.

Who to ask for: heat pump installer / heating engineer.

Certification: None specific for hydraulic checks; MCS-certified installer recommended for system changes.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026