5378Worcester Bosch · Bosch Compress 5800i AW (R290 monobloc)

5378 on a Worcester Bosch Bosch Compress 5800i AW: Info: outdoor unit defrost fault

Short answer

On a Worcester Bosch heat pump, 5378 means: Info: outdoor unit defrost fault. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Info: outdoor unit defrost fault.

Part involved: defrost, sensor TL2.

When it shows: Info: outdoor unit defrost fault.

Likely causes:

  • Heating system temperature/flow temperature too low; evaporator air flow too low; sensor TL2 defective.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Clears when cause removed.

Manual reset: Reset/acknowledge via UI 800 fault menu after cause removed.

What you can check

  • Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
  • Check the outdoor unit is not blocked by leaves, snow, ice or other debris (do not open the casing).
  • Make sure radiator/UFH thermostats are not all closed.

What the engineer will check

  • Open more thermostats; clean evaporator; check TL2 against sensor tables and replace.

Who to ask for: F-gas refrigeration engineer / heat pump installer.

Certification: F-gas certification (Category I) required for refrigerant circuit work; qualified electrician for electrical work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026