5199Worcester Bosch · Bosch Compress 5800i Hybrid Heat Pump (CSH5800iAW O)

5199 on a Worcester Bosch Bosch Compress 5800i Hybrid Heat Pump: Dry running of the hybrid circulation pump (PH0)

Short answer

On a Worcester Bosch heat pump, 5199 means: Dry running of the hybrid circulation pump (PH0). The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Dry running of the hybrid circulation pump (PH0).

Part involved: hybrid circulation pump PH0.

When it shows: Dry running of the hybrid circulation pump (PH0).

Likely causes:

  • No water in system; air in system.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Clears when cause removed.

Manual reset: Manual 12.1: fault indications can be reset on the control unit in the diagnostic menu with Reset.

What you can check

  • Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
  • Check the heating system pressure gauge reading (Bosch guidance is typically 1-2 bar when cold); report low pressure to your installer.
  • If the hybrid system stops using the heat pump, the gas boiler may still provide heat - do not attempt repairs yourself.

What the engineer will check

  • Fill system; start bleeding function.

Who to ask for: heat pump installer / heating engineer.

Certification: None specific for hydraulic checks; MCS-certified installer recommended for system changes.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.