SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Viessmann
E691Viessmann · Vitocal 100-A

E691 on a Viessmann Vitocal 100-A: Low pressure transducer failure (blocks: Machine)

Short answer

On a Viessmann heat pump, E691 means: Low pressure transducer failure (blocks: Machine). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Low pressure transducer failure (blocks: Machine).

Part involved: Low pressure transducer failure.

When it shows: The alarm is triggered if any connected or enabled probe is short-circuited or interrupted. The alarm also triggers if the upper limit (100°C) or the lower limit (-50°C) of the probes is exceeded. A probe figured as sanitary probe will not trigger any alarms if ….

Likely causes:

  • The alarm is triggered if any connected or enabled probe is short-circuited or interrupted. The alarm also triggers if the upper limit (100°C) or the ….

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated.

Manual reset: Placing the controller in OFF mode resets alarms and hour counters (6167577 s.13, printed p.34); if alarms persist when switched on, contact technical assistance.

What you can check

  • Note the E-code (e.g. E006) shown on the Vitocal 100-A controller display and give it to your installer.
  • Per 6167577 s.13, switching the controller to OFF resets alarms; if the alarm is still present when switched back on, stop and contact your installer/Viessmann technical assistance (do not keep cycling it).
  • Check the heat pump breaker/isolator in the consumer unit is ON and the outdoor unit is not blocked by leaves, debris or snow.
  • Check the heating system pressure gauge and make sure the filling loop is closed.

What the engineer will check

  • Check the related sensor/transducer wiring and value (probe short-circuit/open circuit or outside -50..100 °C).
  • Read alarm log (Hist) on controller; contact Viessmann technical assistance if alarm persists.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026