90Vaillant · geoTHERM (VWS/VWW ../2, VWS ../3)

90 on a Vaillant geoTHERM: Heating system pressure too low (< 0.5 bar; restarts automatically above 0.7 bar)

Short answer

On a Vaillant heat pump, 90 means: Heating system pressure too low (< 0.5 bar; restarts automatically above 0.7 bar). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Heating system pressure too low (< 0.5 bar; restarts automatically above 0.7 bar).

Part involved: Heating system pressure too low.

When it shows: Heating system pressure too low (< 0.5 bar; restarts automatically above 0.7 bar).

Likely causes:

  • Pressure drop in heating system due to leakage, air lock or defective expansion vessel; rear screw couplings or 3-way valve compression fittings leaking.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes - restarts automatically when pressure recovers (errors 90/91 need no reset).

Manual reset: not required.

What you can check

  • Note the full code and text shown on the display (and the date/time it appeared). Read the heating system pressure gauge (should be above 0.7 bar for restart). The geoTHERM manuals say only an expert technician should remedy faults - ask your installer to top up and find the leak. Look for visible leaks at the heat pump connections.

What the engineer will check

  • Check heating system for leaks, top up water, bleed, check expansion vessel; retighten couplings/fittings.

Who to ask for: Vaillant-trained heat pump installer/engineer (MCS-certified installer).

Certification: MCS installer certification; Vaillant product training recommended.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the geoTHERM (VWS/VWW ../2, VWS ../3): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026