TP on a Trianco heat pump: Low AT Power-Off Prot

Short answer

On a Trianco heat pump, TP means: Low AT Power-Off Prot. The manual does not say whether the heat pump stops. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the Activair Commercial R290 50kW (FG9550)

The manual says: Low AT Power-Off Prot.

Part involved: ambient / water temperature protection logic.

Likely causes:

  • Excessively low ambient temperature.

On the Activair High Temperature R290 (5/9/15/22kW)

The manual says: Low Ambient Temp. Protection.

Part involved: ambient / water temperature protection logic.

Likely causes:

  • Ambient temp <= -30C.

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

The manual says: Low AT Protection.

Part involved: ambient / water temperature protection logic.

Likely causes:

  • The ambient temp. is low.

On the Activair Pro (AI) R290 6/12/17kW

The manual says: Low AT Protection.

Part involved: ambient / water temperature protection logic.

Likely causes:

  • The ambient temp. is low.

Is it safe?

Does the heat pump stop?Not stated
SeverityFault — clears by itself when the condition goes

The manual does not say whether the heat pump stops.

What you can check

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
  • Check the outdoor unit is not blocked by snow, ice build-up or debris.
  • Leave the heat pump powered: frost protection needs a permanent electricity supply.

What the engineer will check

On the Activair Commercial R290 50kW (FG9550)

  • Adjust the ambient temperature (clears when ambient rises).

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer.

On the Activair High Temperature R290 (5/9/15/22kW)

  • Check the ambient temp.
  • When ambient temp >= -28C, the fault will disappear.

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer.

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

  • Check the ambient temp value.

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer.

On the Activair Pro (AI) R290 6/12/17kW

  • Check the ambient temp value.

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.