E032Trianco

E032 on a Trianco heat pump: Water Flow Switch Prot

Short answer

On a Trianco heat pump, E032 means: Water Flow Switch Prot. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the Activair Commercial R290 50kW (FG9550)

The manual says: Water Flow Switch Prot.

Part involved: water flow / water temperature.

Likely causes:

  • The water system has no or only few water.

On the Activair High Temperature R290 (5/9/15/22kW)

The manual says: Flow Switch Protection.

Part involved: water flow / water temperature.

Likely causes:

  • Flow switch is open.

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

The manual says: Flow Switch Fault.

Part involved: water flow / water temperature.

Likely causes:

  • No water/little water in water system.

On the Activair Pro (AI) R290 6/12/17kW

The manual says: Flow Switch Fault.

Part involved: water flow / water temperature.

Likely causes:

  • No water/little water in water system.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
  • Check the heating system pressure gauge reading (if one is fitted) and tell your engineer if it is below the level set at commissioning; do not attempt to refill unless you have been shown how.

What the engineer will check

On the Activair Commercial R290 50kW (FG9550)

  • Inspect whether the water flow of the water pipe conforms to related requirements and check the water pump for any damages.

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer (manufacturer training recommended).

On the Activair High Temperature R290 (5/9/15/22kW)

  • Detect the connection of cables.
  • Detect the flow switch.
  • Detect the water valve is opened fully.
  • Detect the water pump and the filter.
  • There may be air in the water route.

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer (manufacturer training recommended).

On the Activair R290 Indoor (3.2kW wall hung / 5kW floor standing)

  • Check the pipe water flow and water pump.

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer (manufacturer training recommended).

On the Activair Pro (AI) R290 6/12/17kW

  • Check the pipe water flow and water pump.

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer (manufacturer training recommended).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026