ALRM017 on a Trianco Activair Indoor R32 5/7kW: Plant flowmeter tripped

Short answer

On a Trianco heat pump, ALRM017 means: Plant flowmeter tripped. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Plant flowmeter tripped.

Part involved: water flow / water temperature.

When it shows: PP1 active but PI1 open (with delay).

Likely causes:

  • Check valves closed.
  • 3-way hot/cold diversion valve in wrong position.
  • Air bubbles in the circuit.
  • No consumer with open circuit or 3-way valve.
  • External sieve filter clogged.
  • Plant water pressure incorrect.
  • Circulation pump not working (may need unlocking).

Is it safe?

Does the heat pump stop?Not stated
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Generally automatic when the activation condition clears (conditions must persist e.g. 30 s).

Manual reset: If the alarm trips repeatedly (e.g. 3 times in 1 hour) it must be reset manually by the Technical Assistance Centre (press and hold the reset key until padlock and alarm symbol clear).

What you can check

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
  • Check the heating system pressure gauge reading (if one is fitted) and tell your engineer if it is below the level set at commissioning; do not attempt to refill unless you have been shown how.

What the engineer will check

  • Check for: Check valves closed.
  • Check for: 3-way hot/cold diversion valve in wrong position.
  • Check for: Air bubbles in the circuit.
  • Check for: No consumer with open circuit or 3-way valve.
  • Check for: External sieve filter clogged.
  • Check for: Plant water pressure incorrect.
  • Check for: Circulation pump not working (may need unlocking).

Who to ask for: heating / hydraulics.

Certification: Competent heating engineer (manufacturer training recommended).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.