Heat pumps · Error codes · Trianco
ALRM002Trianco · Activair Indoor R32 5/7kW (FG 9112 / FG 9113)

ALRM002 on a Trianco Activair Indoor R32 5/7kW: Low-pressure switch tripped

Short answer

On a Trianco heat pump, ALRM002 means: Low-pressure switch tripped. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Low-pressure switch tripped.

Part involved: pressure switch / compressor discharge-suction.

When it shows: Open pressure switch MI2 contact.

Likely causes:

  • Insufficient refrigerant charge.
  • Excessive amount of antifreeze.
  • Insufficient air flow to air cooler.

Is it safe?

Does the heat pump stop?Not stated
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Generally automatic when the activation condition clears (conditions must persist e.g. 30 s).

Manual reset: If the alarm trips repeatedly (e.g. 3 times in 1 hour) it must be reset manually by the Technical Assistance Centre (press and hold the reset key until padlock and alarm symbol clear).

What you can check

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
  • Check the outdoor unit is not blocked by debris/snow and has its required clearances.

What the engineer will check

  • Check for: Insufficient refrigerant charge.
  • Check for: Excessive amount of antifreeze.
  • Check for: Insufficient air flow to air cooler.

Who to ask for: refrigeration.

Certification: F-gas certified refrigeration engineer (REFCOM or equivalent).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.