E01Technibel S.A.S. · Technibel PHRIE / PHIE inverter monobloc air-to-water (medium temperature)

E01 on a Technibel S.A.S. Technibel PHRIE / PHIE inverter monobloc air-to-water: Maintenance remote control detected error signal from A2 board - serial signal receiving failure

Short answer

On a Technibel S.A.S. heat pump, E01 means: Maintenance remote control detected error signal from A2 board - serial signal receiving failure. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Maintenance remote control detected error signal from A2 board - serial signal receiving failure.

Likely causes:

  • Remocon connection.
  • A2 address.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Automatic stop; if the fault lasts <30 min it clears automatically, if >30 min it is memorised (AL LED steady) and needs manual reset (A2 RESET button 5 s, system control OFF, or power off).

What you can check

  • Note the code/LED pattern and the model from the rating plate, then contact a heat pump/refrigeration engineer.
  • Check the heat pump's breaker/isolator at the consumer unit is on.

What the engineer will check

  • Check remocon connection.
  • Check address on A2 board.
  • Check A2 board.

Who to ask for: refrigeration / heat pump engineer.

Certification: Electrical competence for work inside the unit.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026