50047 on a Stiebel Eltron WPM heat pump manager / WPMsystem: Repeated instances of message number X-0047 has led to heat pump interlock
Short answer
On a Stiebel Eltron heat pump, 50047 means: Repeated instances of message number X-0047 has led to heat pump interlock. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Repeated instances of message number X-0047 has led to heat pump interlock.
Part involved: compressor / expansion valve / pressure switches.
When it shows: Repeated instances of message number X-0047 has led to heat pump interlock.
Likely causes:
- Possible ingress of refrigerant into the heating circuit. Do not bleed the radiators. Observe the procedure for venting heating systems. Remove the cause. Then carry out a reset of the heat pump.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: no.
Manual reset: yes - reset of heat pump via WPM after cause removed (contractor).
What you can check
- Do NOT bleed radiators (Stiebel R290 manual: possible refrigerant ingress into heating water); contact your installer/service department.
- Read and note the full message code and time from the WPM display (DIAGNOSIS / NOTIFICATIONLIST if accessible without a code).
- Check the heat pump and controller circuit breakers/isolators at the consumer unit are on.
- Check the outdoor unit air intake/discharge is not blocked by leaves, snow or ice (air source units).
What the engineer will check
- Possible ingress of refrigerant into the heating circuit. Do not bleed the radiators. Observe the procedure for venting heating systems. Remove the cause. Then carry out a reset of the heat pump.
Who to ask for: F-gas/refrigeration-qualified heat pump engineer (R290/A3 flammable-refrigerant competence for R290 models).
Certification: F-gas certification for fluorinated refrigerants (R410A/R454C); flammable refrigerant (R290) handling training for R290 models.
What you might notice
Sources
- WPM notification list (WPM V2.9) - multilingual; English section pp.15-26 (DOC-00081866) ↗ · WPM V2.9 · page 26 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026