10004 on a Stiebel Eltron WPM heat pump manager / WPMsystem: The high pressure switch has responded

Short answer

On a Stiebel Eltron heat pump, 10004 means: The high pressure switch has responded. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: The high pressure switch has responded.

Part involved: compressor / expansion valve / pressure switches.

When it shows: The high pressure switch has responded.

Likely causes:

  • Check the flow rate and sensor connection on the heating side. Check the selected room temperature or heating curve.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes - heat pump restarts after idle time (~10-12 min); locks out after 5 faults in 2 h run.

Manual reset: after 5 faults in 2 h: IWS/WPM reset.

What you can check

  • Read and note the full message code and time from the WPM display (DIAGNOSIS / NOTIFICATIONLIST if accessible without a code).
  • Check the heat pump and controller circuit breakers/isolators at the consumer unit are on.
  • Check the heating system pressure gauge reading is in the normal range stated by your installer.
  • Check the outdoor unit air intake/discharge is not blocked by leaves, snow or ice (air source units).
  • Check room thermostat / set temperatures are not set unusually high.

What the engineer will check

  • Check the flow rate and sensor connection on the heating side. Check the selected room temperature or heating curve.

Who to ask for: F-gas/refrigeration-qualified heat pump engineer (R290/A3 flammable-refrigerant competence for R290 models).

Certification: F-gas certification for fluorinated refrigerants (R410A/R454C); flammable refrigerant (R290) handling training for R290 models.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026