30468 on a Stiebel Eltron WPM heat pump manager / WPMsystem: Temperature limiter for maximum oil sump temperature has responded
Short answer
On a Stiebel Eltron heat pump, 30468 means: Temperature limiter for maximum oil sump temperature has responded. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Temperature limiter for maximum oil sump temperature has responded.
Part involved: compressor or fan inverter.
When it shows: Temperature limiter for maximum oil sump temperature has responded.
Likely causes:
- Compressor incorrectly connected to the inverter.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — clears by itself when the condition goes |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: yes - heat pump restarts after idle time (~10-12 min); locks out after 5 faults in 2 h run.
Manual reset: after 5 faults in 2 h: IWS/WPM reset.
What you can check
- Read and note the full message code and time from the WPM display (DIAGNOSIS / NOTIFICATIONLIST if accessible without a code).
- Check the heat pump and controller circuit breakers/isolators at the consumer unit are on.
What the engineer will check
- Compressor incorrectly connected to the inverter.
Who to ask for: Heat pump service engineer (electrical/controls).
Certification: Qualified electrician competence for live-work on appliance electrics.
What you might notice
Sources
- WPM notification list (WPM V2.9) - multilingual; English section pp.15-26 (DOC-00081866) ↗ · WPM V2.9 · page 25 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026