30172 on a Stiebel Eltron WPM heat pump manager / WPMsystem: Float switch has tripped

Short answer

On a Stiebel Eltron heat pump, 30172 means: Float switch has tripped. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Float switch has tripped.

Part involved: water flow / pump / booster heater.

When it shows: Float switch has tripped.

Likely causes:

  • Check the condensate pump and the condensate drain.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes - heat pump restarts after idle time (~10-12 min); locks out after 5 faults in 2 h run.

Manual reset: after 5 faults in 2 h: IWS/WPM reset.

What you can check

  • Read and note the full message code and time from the WPM display (DIAGNOSIS / NOTIFICATIONLIST if accessible without a code).
  • Check the heat pump and controller circuit breakers/isolators at the consumer unit are on.
  • Check the heating system pressure gauge reading is in the normal range stated by your installer.
  • Check the outdoor unit air intake/discharge is not blocked by leaves, snow or ice (air source units).

What the engineer will check

  • Check the condensate pump and the condensate drain.

Who to ask for: Heating / heat pump engineer.