Heat pumps · Error codes · Stiebel Eltron
10028Stiebel Eltron · WPM heat pump manager / WPMsystem (controller platform)

10028 on a Stiebel Eltron WPM heat pump manager / WPMsystem: Superheating of the refrigerant at the evaporator discharge or the compressor intake for too long below the permissible limit

Short answer

On a Stiebel Eltron heat pump, 10028 means: Superheating of the refrigerant at the evaporator discharge or the compressor intake for too long below the permissible limit. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Superheating of the refrigerant at the evaporator discharge or the compressor intake for too long below the permissible limit.

Part involved: compressor / expansion valve / pressure switches.

When it shows: Superheating of the refrigerant at the evaporator discharge or the compressor intake for too long below the permissible limit.

Likely causes:

  • Expansion valve not working correctly.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes - heat pump restarts after idle time (~10-12 min); locks out after 5 faults in 2 h run.

Manual reset: after 5 faults in 2 h: IWS/WPM reset.

What you can check

  • Read and note the full message code and time from the WPM display (DIAGNOSIS / NOTIFICATIONLIST if accessible without a code).
  • Check the heat pump and controller circuit breakers/isolators at the consumer unit are on.
  • Check the outdoor unit air intake/discharge is not blocked by leaves, snow or ice (air source units).

What the engineer will check

  • Expansion valve not working correctly.

Who to ask for: F-gas/refrigeration-qualified heat pump engineer (R290/A3 flammable-refrigerant competence for R290 models).

Certification: F-gas certification for fluorinated refrigerants (R410A/R454C); flammable refrigerant (R290) handling training for R290 models.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.