SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Rinnai
E931Rinnai

E931 on a Rinnai heat pump: Comunication error with main controller

Short answer

On a Rinnai heat pump, E931 means: Comunication error with main controller. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 24 September 2026 · 2 sources

What it means

On the HPI (HPi32) R32 monobloc

The manual says: Comunication error with main controller.

Part involved: see manual.

On the R290 monobloc (HPR290)

The manual says: Internal communication error.

Part involved: controller / PCB communication.

Is it safe?

On the HPI (HPi32) R32 monobloc

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the R290 monobloc (HPR290)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

What you can check

  • Note the code shown on the controller and the model number on the unit's rating label before contacting your installer.
  • Check that the heat pump's isolator and consumer-unit breaker are on; do not open any casing.

What the engineer will check

On the HPI (HPi32) R32 monobloc

  • Follow the manufacturer's troubleshooting for this code.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas and flammable-refrigerant (R32/R290) handling competence for any refrigerant-circuit work.

On the R290 monobloc (HPR290)

  • Check communication cables and connectors between boards/controller.
  • Check board power supplies.
  • Check addressing and firmware compatibility.
  • Replace the faulty board.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas and flammable-refrigerant (R32/R290) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026