420 on a Mitsubishi Heavy Industries Air-Conditioning Europe Hydrolution: Temp. com. fault w. inverter: A temporary communication fault in the inverter has occurred

Short answer

On a Mitsubishi Heavy Industries Air-Conditioning Europe heat pump, 420 means: Temp. com. fault w. inverter: A temporary communication fault in the inverter has occurred. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Temp. com. fault w. inverter: A temporary communication fault in the inverter has occurred.

Part involved: Temp. com. fault w. inverter.

When it shows: A temporary communication fault in the inverter has occurred.

Likely causes:

  • Main and group fuses and cable to the inverter; communication cable between PCB and inverter.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes.

Manual reset: no.

What you can check

  • Note the alarm number/text shown on the display. Check the consumer-unit breakers/isolators for the indoor and outdoor units are on. Check the outdoor unit is not blocked by leaves, snow or ice and its drain is clear (look only - do not open the casing). This is an information message; it resets automatically when the cause is removed.

What the engineer will check

  • Per manual 'May be due to': Main and group fuses and cable to the inverter; communication cable between PCB and inverter. Check communication cabling, DIP switches and power to accessory/boards.

Who to ask for: Heat pump / refrigeration engineer (manufacturer-trained).

Certification: F-gas certification for refrigerant-circuit work; electrical competence (Part P/18th Edition) for PCB/wiring.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.