Heat pumps · Error codes · Mitsubishi Heavy Industries Air-Conditioning Europe
334Mitsubishi Heavy Industries Air-Conditioning Europe · Hydrolution (split, FDCW outdoor units)

334 on a Mitsubishi Heavy Industries Air-Conditioning Europe Hydrolution: Max. incoming temp. exceeded: BT3 higher than 65 C in heating mode

Short answer

On a Mitsubishi Heavy Industries Air-Conditioning Europe heat pump, 334 means: Max. incoming temp. exceeded: BT3 higher than 65 C in heating mode. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Max. incoming temp. exceeded: BT3 higher than 65 C in heating mode.

Part involved: Max. incoming temp. exceeded.

When it shows: BT3 higher than 65 C in heating mode.

Likely causes:

  • Undersized heating system; incorrect heating curve; flow related; additional heat incorrectly connected.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes.

Manual reset: no.

What you can check

  • Note the alarm number/text shown on the display. Check the consumer-unit breakers/isolators for the indoor and outdoor units are on. Check radiator/underfloor thermostats in the house are not all closed (user manual). Check the heating system pressure gauge reads in the normal range (about 0.5-1.5 bar when cold for Hydrolution per user manual). This is an information message; it resets automatically when the cause is removed.

What the engineer will check

  • Per manual 'May be due to': Undersized heating system; incorrect heating curve; flow related; additional heat incorrectly connected. Check sensor wiring/resistance, settings, flow (particle filter, pump) and supply as applicable.

Who to ask for: Heat pump / refrigeration engineer (manufacturer-trained).

Certification: F-gas certification for refrigerant-circuit work; electrical competence (Part P/18th Edition) for PCB/wiring.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026