Heat pumps · Error codes · Mitsubishi Heavy Industries Air-Conditioning Europe
319-321Mitsubishi Heavy Industries Air-Conditioning Europe · Hydrolution (split, FDCW outdoor units)

319-321 on a Mitsubishi Heavy Industries Air-Conditioning Europe Hydrolution: Comm flt with EB10x -GP12: Communication with the accessory board for GP12 (EB103/4, EB105/6, EB107/8) missing for 15 seconds

Short answer

On a Mitsubishi Heavy Industries Air-Conditioning Europe heat pump, 319-321 means: Comm flt with EB10x -GP12: Communication with the accessory board for GP12 (EB103/4, EB105/6, EB107/8) missing for 15 seconds. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Comm flt with EB10x -GP12: Communication with the accessory board for GP12 (EB103/4, EB105/6, EB107/8) missing for 15 seconds.

Part involved: Comm flt with EB10x -GP12.

When it shows: Communication with the accessory board for GP12 (EB103/4, EB105/6, EB107/8) missing for 15 seconds.

Likely causes:

  • Defective communication cables; accessory activated in display but not connected; incorrectly connected communication cable; incorrectly set DIP switch; no electrical supply to the accessory board.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no.

Manual reset: yes (select 'reset alarm' in the alarm menu).

What you can check

  • Note the alarm number/text shown on the display. Check the consumer-unit breakers/isolators for the indoor and outdoor units are on. On the RC-HY controller you may select 'reset alarm' once (installation manual: 'in most cases it is enough'); if the red lamp stays or the alarm returns, select 'aid mode' (if enabled) or 'add. heat only' in menu 4.2 and contact the installer.

What the engineer will check

  • Per manual 'May be due to': Defective communication cables; accessory activated in display but not connected; incorrectly connected communication cable; incorrectly set DIP switch; no electrical supply to the accessory board. Check communication cabling, DIP switches and power to accessory/boards.

Who to ask for: Heat pump / refrigeration engineer (manufacturer-trained).

Certification: F-gas certification for refrigerant-circuit work; electrical competence (Part P/18th Edition) for PCB/wiring.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026