SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Mitsubishi Heavy Industries Air-Conditioning Europe
221Mitsubishi Heavy Industries Air-Conditioning Europe · Hydrolution (split, FDCW outdoor units)

221 on a Mitsubishi Heavy Industries Air-Conditioning Europe Hydrolution: Low pressure alarm: Too low value on the low pressure sensor 3 times within 60 minutes

Short answer

On a Mitsubishi Heavy Industries Air-Conditioning Europe heat pump, 221 means: Low pressure alarm: Too low value on the low pressure sensor 3 times within 60 minutes. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Low pressure alarm: Too low value on the low pressure sensor 3 times within 60 minutes.

Part involved: Low pressure alarm.

When it shows: Too low value on the low pressure sensor 3 times within 60 minutes.

Likely causes:

  • Open/short circuit on input for low pressure sensor; defective low pressure sensor; defective control board in outdoor unit; open/short circuit on input for suction gas sensor (Tho-S).

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: yes (select 'reset alarm' in the alarm menu).

What you can check

  • Note the alarm number/text shown on the display. Check the consumer-unit breakers/isolators for the indoor and outdoor units are on. Check the outdoor unit is not blocked by leaves, snow or ice and its drain is clear (look only - do not open the casing). On the RC-HY controller you may select 'reset alarm' once (installation manual: 'in most cases it is enough'); if the red lamp stays or the alarm returns, select 'aid mode' (if enabled) or 'add. heat only' in menu 4.2 and contact the installer.

What the engineer will check

  • Per manual 'May be due to': Open/short circuit on input for low pressure sensor; defective low pressure sensor; defective control board in outdoor unit; open/short circuit on input for suction gas sensor (Tho-S). Refrigerant/outdoor-unit work (service valves, charge, sensors Tho-R/A/D/S, LPT, 63H1, fan motor, inverter/control PCBs) must be done by an F-gas certified engineer.

Who to ask for: Heat pump / refrigeration engineer (manufacturer-trained).

Certification: F-gas certification for refrigerant-circuit work; electrical competence (Part P/18th Edition) for PCB/wiring.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026