UP on a Mitsubishi Electric heat pump: Overcurrent abnormality: overcurrent detected by secondary current

Short answer

On a Mitsubishi Electric heat pump, UP means: Overcurrent abnormality: overcurrent detected by secondary current. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 10 sources

What it means

On the Ecodan Co2 Quhz

The manuals for this range word it in different ways:

  • Overcurrent abnormality: overcurrent detected by secondary current.
  • Abnormality of circuit to detect AC current: defective primary current detection sensor for 2 minutes.
  • Service mode end display: service mode (outdoor run with compressor relay connector CN61 disconnected) continued for 20 minutes.

Part involved: Compressor / outdoor inverter PCB / LEV; Outdoor inverter PCB current sensor; Compressor relay connector CN61 / outdoor inverter PCB.

When it shows: Overcurrent detected by secondary current Defective primary current detection sensor detected continuously for 2 minutes Service mode continued for 20 minutes.

Likely causes:

  • 1 Defective compressor lead wire relay connector/terminal connection; 2 Defective outdoor inverter PCB (Q821, IC700, overcurrent detection circuit); 3 Defective LEV coil; 4 Defective LEV unit (locked, foreign matter); 5 Defective compressor (coil short/open, locked); 6 Power waveform distortion, noise.
  • 1 Defective outdoor inverter PCB.
  • 1 Compressor relay connector disconnected; 2 Defective outdoor inverter PCB.

On the Ecodan Hydrodan

The manual says: Compressor overcurrent interruption: overcurrent of DC bus or compressor after 30 seconds of compressor operation.

Part involved: Compressor / outdoor power & controller boards.

When it shows: Overcurrent of DC bus or compressor detected after compressor has run 30 s.

Likely causes:

  • See service handbook.

On the Ecodan Puhz Sw Split

The manual says: Compressor overcurrent interruption: overcurrent of DC bus or compressor after 30 seconds of compressor operation.

Part involved: Compressor / outdoor power & controller boards.

When it shows: Overcurrent of DC bus or compressor detected after compressor has run 30 s.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Looseness, disconnection or reverse of compressor wiring; 3 Defective outdoor fan; 4 Short cycle of outdoor unit; 5 Defective input circuit of outdoor controller board; 6 Defective compressor; 7 Defective outdoor power circuit board; 8 DIP switch (model select) setting difference on outdoor controller board.

On the Ecodan Puhz W Monobloc

The manual says: Compressor overcurrent interruption: overcurrent of DC bus or compressor after 30 seconds of compressor operation.

Part involved: Compressor / outdoor power & controller boards.

When it shows: Overcurrent of DC bus or compressor detected after compressor has run 30 s.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Compressor wiring loose/reversed; 3 Defective outdoor fan; 4 Short cycle; 5 Defective input circuit of outdoor controller board; 6 Defective compressor; 7 Decreased water flow; 8 Clogged water filter; 9 Clogged plate HEX; 10 Locked water pump; 11 Malfunction of water pump.

On the Ecodan R290 Puz Wz

The manual says: Compressor overcurrent interruption: overcurrent of DC bus or compressor after 30 seconds of compressor operation.

Part involved: Compressor / outdoor power & controller boards.

When it shows: Overcurrent of DC bus or compressor detected after compressor has run 30 s.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Looseness, disconnection or reverse of compressor wiring; 3 Defective outdoor fan; 4 Short cycle of outdoor unit; 5 Defective input circuit of outdoor controller board; 6 Defective compressor; 7 Defective outdoor power circuit board; 8 DIP switch (model select) setting difference on outdoor controller board.

On the Ecodan R32 Puz Wm

The manual says: Compressor overcurrent interruption: overcurrent of DC bus or compressor after 30 seconds of compressor operation.

Part involved: Compressor / outdoor power & controller boards.

When it shows: Overcurrent of DC bus or compressor detected after compressor has run 30 s.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Looseness, disconnection or reverse of compressor wiring; 3 Defective outdoor fan; 4 Short cycle of outdoor unit; 5 Defective input circuit of outdoor controller board; 6 Defective compressor; 7 Defective outdoor power circuit board; 8 DIP switch (model select) setting difference on outdoor controller board.

On the Ecodan R32 Zubadan Puz Hwm

The manual says: Compressor overcurrent interruption: overcurrent of DC bus or compressor after 30 seconds of compressor operation.

Part involved: Compressor / outdoor power & controller boards.

When it shows: Overcurrent of DC bus or compressor detected after compressor has run 30 s.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Compressor wiring loose/reversed; 3 Defective outdoor fan; 4 Short cycle; 5 Defective input circuit of outdoor controller board; 6 Defective compressor; 7 Decreased water flow; 8 Clogged water filter; 9 Clogged plate HEX; 10 Locked water pump; 11 Malfunction of water pump.

On the Ecodan Ultra Quiet Puhz W Vaa

The manual says: Compressor overcurrent interruption: overcurrent of DC bus or compressor after 30 seconds of compressor operation.

Part involved: Compressor / outdoor power & controller boards.

When it shows: Overcurrent of DC bus or compressor detected after compressor has run 30 s.

Likely causes:

  • 1 Outdoor stop valve closed; 2 Decrease of power supply voltage; 3 Compressor wiring loose/reversed; 4 Defective fan; 5 Short cycle; 6 Defective input circuit of outdoor controller board; 7 Defective compressor; 8 Defective outdoor power board; 9 DIP switch setting difference.

On the Ecodan Zubadan Puhz Hw Monobloc

The manual says: Compressor overcurrent interruption: overcurrent of DC bus or compressor after 30 seconds of compressor operation.

Part involved: Compressor / outdoor power & controller boards.

When it shows: Overcurrent of DC bus or compressor detected after compressor has run 30 s.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Compressor wiring loose/reversed; 3 Defective outdoor fan; 4 Short cycle; 5 Defective input circuit of outdoor controller board; 6 Defective compressor; 7 Decreased water flow; 8 Clogged water filter; 9 Clogged plate HEX; 10 Locked water pump; 11 Malfunction of water pump.

On the Ecodan Zubadan Puhz Shw Split

The manual says: Compressor overcurrent interruption: overcurrent of DC bus or compressor after 30 seconds of compressor operation.

Part involved: Compressor / outdoor power & controller boards.

When it shows: Overcurrent of DC bus or compressor detected after compressor has run 30 s.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Looseness, disconnection or reverse of compressor wiring; 3 Defective outdoor fan; 4 Short cycle of outdoor unit; 5 Defective input circuit of outdoor controller board; 6 Defective compressor; 7 Defective outdoor power circuit board; 8 DIP switch (model select) setting difference on outdoor controller board.

Is it safe?

On the Ecodan Co2 Quhz

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering.

Manual reset: Outdoor error cancelled by switching the cylinder unit earth leakage circuit breaker OFF, waiting until the outdoor board LEDs go out (about 1 minute), then ON again (service manual GHH15010).

On the Ecodan Hydrodan

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

On the Ecodan Puhz Sw Split

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

On the Ecodan Puhz W Monobloc

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

On the Ecodan R290 Puz Wz

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

On the Ecodan R32 Puz Wm

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

On the Ecodan R32 Zubadan Puz Hwm

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

On the Ecodan Ultra Quiet Puhz W Vaa

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

On the Ecodan Zubadan Puhz Hw Monobloc

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

On the Ecodan Zubadan Puhz Shw Split

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

What you can check

On the Ecodan Co2 Quhz

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.
  • Note the code, unit and ref. address shown on the main remote controller and contact your installer (Mitsubishi user manuals: 'Make a note of the error code number and contact installer'). Check the heat pump breaker/isolator at the consumer unit is on and read the primary system pressure gauge (if fitted) so you can report it. A single reset from the main remote controller (RESET, then Yes) may be tried; if the code returns, do not keep resetting. Do not open the outdoor unit, cylinder/hydrobox or any casing.

On the Ecodan Hydrodan

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

On the Ecodan Puhz Sw Split

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

On the Ecodan Puhz W Monobloc

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

On the Ecodan R290 Puz Wz

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

On the Ecodan R32 Puz Wm

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

On the Ecodan R32 Zubadan Puz Hwm

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

On the Ecodan Ultra Quiet Puhz W Vaa

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

On the Ecodan Zubadan Puhz Hw Monobloc

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

On the Ecodan Zubadan Puhz Shw Split

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

What the engineer will check

On the Ecodan Co2 Quhz

  • 1 Check continuity of compressor and lead wires, reconnect relay connector/terminal (breaker OFF first); 2 Replace outdoor inverter PCB; 3 Check LEV coil/CN724; 4-5 Replace outdoor unit; 6 Check power waveform.
  • 1 Replace the outdoor inverter PCB.
  • 1 Turn cylinder unit earth leakage breaker OFF before reconnecting compressor relay connector; 2 Replace outdoor inverter PCB.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics); Mitsubishi Ecodan-trained heat pump engineer (controls / wiring).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience.

On the Ecodan Hydrodan

  • See service handbook.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R32, A2L mildly flammable).

On the Ecodan Puhz Sw Split

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check fan; 4 Solve short cycle; 5 Replace outdoor controller board (first check U-V-W output voltages are balanced with compressor disconnected); 6 Check compressor; 7 Replace outdoor power circuit board; 8 Check DIP switch settings.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R410A).

On the Ecodan Puhz W Monobloc

  • 1 Check power supply; 2 Correct compressor wiring; 3 Check outdoor fan; 4 Solve short cycle; 5 Replace outdoor controller board (check U-V-W output first); 6 Check compressor; 7-11 Check water circuit and repair.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R410A).

On the Ecodan R290 Puz Wz

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check fan; 4 Solve short cycle; 5 Replace outdoor controller board (first check U-V-W output voltages are balanced with compressor disconnected); 6 Check compressor; 7 Replace outdoor power circuit board; 8 Check DIP switch settings.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification plus competence for flammable A3 refrigerant (R290).

On the Ecodan R32 Puz Wm

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check fan; 4 Solve short cycle; 5 Replace outdoor controller board (first check U-V-W output voltages are balanced with compressor disconnected); 6 Check compressor; 7 Replace outdoor power circuit board; 8 Check DIP switch settings.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R32, A2L mildly flammable).

On the Ecodan R32 Zubadan Puz Hwm

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check fan; 4 Solve short cycle; 5 Replace outdoor controller board (first check U-V-W output voltages are balanced with compressor disconnected); 6 Check compressor; 7 Replace outdoor power circuit board; 8 Check DIP switch settings.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R32, A2L mildly flammable).

On the Ecodan Ultra Quiet Puhz W Vaa

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check fan; 4 Solve short cycle; 5 Replace outdoor controller board (first check U-V-W output voltages are balanced with compressor disconnected); 6 Check compressor; 7 Replace outdoor power circuit board; 8 Check DIP switch settings.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R410A).

On the Ecodan Zubadan Puhz Hw Monobloc

  • 1 Check power supply; 2 Correct compressor wiring; 3 Check outdoor fan; 4 Solve short cycle; 5 Replace outdoor controller board (check U-V-W output first); 6 Check compressor; 7-11 Check water circuit and repair.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R410A).

On the Ecodan Zubadan Puhz Shw Split

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check fan; 4 Solve short cycle; 5 Replace outdoor controller board (first check U-V-W output voltages are balanced with compressor disconnected); 6 Check compressor; 7 Replace outdoor power circuit board; 8 Check DIP switch settings.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R410A).

What you might notice

What owners and engineers report

2 owner and engineer reports mention this.

  • Heat pump will not start on the Ecodan Puhz W Monobloc: 1 report
  • Keeps stopping / cutting out on the Ecodan R32 Puz Wm: 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.