FD on a Mitsubishi Electric Ecodan Co2 Quhz: Detection of abnormal AC voltage: input voltage to outdoor unit 70 V or less

Short answer

On a Mitsubishi Electric heat pump, FD means: Detection of abnormal AC voltage: input voltage to outdoor unit 70 V or less. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Detection of abnormal AC voltage: input voltage to outdoor unit 70 V or less.

Part involved: Power supply / transmission line / earth leakage breaker.

When it shows: Input voltage to outdoor unit 70 V or less.

Likely causes:

  • 1 Low power supply voltage (inappropriate supply, defective transmission line or connection); 2 Erroneous operation of earth leakage circuit breaker (switched back on before outdoor LEDs went out); 3 Defective outdoor inverter PCB.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering.

Manual reset: Outdoor error cancelled by switching the cylinder unit earth leakage circuit breaker OFF, waiting until the outdoor board LEDs go out (about 1 minute), then ON again (service manual GHH15010).

What you can check

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer (Mitsubishi user manuals: 'Make a note of the error code number and contact installer'). Check the heat pump breaker/isolator at the consumer unit is on and read the primary system pressure gauge (if fitted) so you can report it. A single reset from the main remote controller (RESET, then Yes) may be tried; if the code returns, do not keep resetting. Do not open the outdoor unit, cylinder/hydrobox or any casing. Check that the heat pump's dedicated breaker/isolator (and, where fitted, the separate indoor-unit supply) is switched on; if it trips again, leave it off.

What the engineer will check

  • 1 Check supply voltage, replace/correct power transmission line; 2 Perform a reset (wait ~1 min for outdoor LEDs to go out before switching breaker back on); 3 Replace outdoor inverter PCB.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.