Heat pumps · Error codes · Lailey and Coates Ltd
P15Lailey and Coates Ltd · Lailey & Coates LCM monobloc (LCM-06/09/17)

P15 on a Lailey and Coates Ltd Lailey & Coates LCM monobloc: High Pressure Protection fault

Short answer

On a Lailey and Coates Ltd heat pump, P15 means: High Pressure Protection fault. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: High Pressure Protection fault.

Likely causes:

  • Flow restrictions within the wet system.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.
  • Check the outdoor unit/air grilles are not blocked by debris, leaves or snow.

What the engineer will check

  • Check there is no air in the system.
  • Check no blockages in any pipework.
  • Check diverter valves are set correctly and not blocking flow.
  • Check all pumps in the system are working and water flow rate is sufficient.
  • Check water flow first (high pressure is often caused by low flow).
  • Check refrigerant pressures/temperatures with gauges (F-gas qualified).
  • Check for refrigerant leak or blockage, EEV operation and pressure switches/transducers.

Who to ask for: refrigeration / F-gas heat pump engineer.

Certification: F-gas certification (Category I) for refrigerant circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026