Heat pumps · Error codes · Lailey and Coates Ltd
E02Lailey and Coates Ltd · Lailey & Coates LCM monobloc (LCM-06/09/17)

E02 on a Lailey and Coates Ltd Lailey & Coates LCM monobloc: LCD controller communication failure

Short answer

On a Lailey and Coates Ltd heat pump, E02 means: LCD controller communication failure. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: LCD controller communication failure.

Likely causes:

  • Cable fault between LCD unit and control box PCB.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heat pump's breaker/isolator at the consumer unit is switched on (do not repeatedly reset if it trips).

What the engineer will check

  • Check cable to LCD unit and control box PCB.
  • Check communication cable between controller/PCB/driver board (type, polarity, termination).
  • Check power supply to the remote module.
  • Replace faulty PCB/controller if wiring is sound.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026