SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Kensa
A2Kensa

A2 on a Kensa heat pump: Ground return temperature T6 below the Heating Mode anti-freeze limit (right-hand compressor, twin units only)

Short answer

On a Kensa heat pump, A2 means: Ground return temperature T6 below the Heating Mode anti-freeze limit (right-hand compressor, twin units only). The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manual says: Ground return temperature T6 below the Heating Mode anti-freeze limit (right-hand compressor, twin units only).

Part involved: T6 ground return sensor / ground circuit.

When it shows: Error level per manual: Fault or Warning.

Likely causes:

  • Insufficient ground-side flow, ground pump failure, low antifreeze concentration, incorrect ground temperature settings.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes - clears when condition clears (per manual action text).

Manual reset: unknown.

What you can check

  • Note the code shown on the controller/LED; check the heat pump isolator and consumer-unit breaker are on; check thermostat/timer settings.

What the engineer will check

  • Follow Kensa fault table actions: Insufficient ground-side flow, ground pump failure, low antifreeze concentration, incorrect ground temperature settings. As A1 for compressor 2.

Who to ask for: GSHP / ground-loop installer.

Certification: MCS-certified GSHP installer recommended; Kensa-trained.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026