SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Intergas
n016Intergas · Xtend hybrid heat pump

n016 on an Intergas Xtend hybrid heat pump: Abnormal Delta-T between the flow and return temperature values

Short answer

On an Intergas heat pump, n016 means: Abnormal Delta-T between the flow and return temperature values. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Abnormal Delta-T between the flow and return temperature values.

Part involved: flow switch / circulation pump.

Likely causes:

  • Sensors T03/T04 connected or mounted incorrectly; check the system flow.

Is it safe?

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: unknown.

What you can check

  • Note the code shown on the controller and the model number on the unit's rating label before contacting your installer.
  • Check that the heat pump's isolator and consumer-unit breaker are on; do not open any casing.

What the engineer will check

  • Check the circulation pump runs and the strainer/filter is clean.
  • Vent air from the system.
  • Check the flow switch/flowmeter and its wiring.
  • Check isolation valves are open and minimum flow/volume is met.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas and flammable-refrigerant (R32/R290) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026