SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Grant
P25Grant · Aerona 290

P25 on a Grant Aerona 290: Outlet pressure sensor failure

Short answer

On a Grant heat pump, P25 means: Outlet pressure sensor failure. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Outlet pressure sensor failure.

Part involved: water pressure sensor / hydraulic PCB.

Likely causes:

  • Pressure sensor incorrectly connected.
  • Sensor failure.
  • The hydraulic PCB is faulty.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in DOC 0204.

Manual reset: DOC 0204 s11.1: once the fault is resolved, reset by turning the unit OFF and back ON; s11.5: power cycle can be done from the Aerona Smart Controller touchscreen instead of the external isolator (installer procedure).

What you can check

  • Note the exact code shown on the controller display and tell your installer or Grant-trained engineer.
  • Check the heating system pressure gauge (if one is fitted) and report a low reading to your installer; make sure the filling loop valves are closed.

What the engineer will check

  • Check correct connection of sensor.
  • Use a multimeter to check if sensor has short circuit or is faulty; replace.
  • Check the hydraulic PCB; replace if faulty.

Who to ask for: Grant-trained heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026