P21 on a Grant Aerona 290: Abnormal operation of DC pump

Short answer

On a Grant heat pump, P21 means: Abnormal operation of DC pump. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Abnormal operation of DC pump.

Part involved: DC circulating pump / hydraulic PCB.

Likely causes:

  • The water pump is faulty or stuck.
  • The system lacks water or is blocked.
  • Faulty connection between water pump and hydraulic PCB.
  • The hydraulic PCB is faulty.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in DOC 0204.

Manual reset: DOC 0204 s11.1: once the fault is resolved, reset by turning the unit OFF and back ON; s11.5: power cycle can be done from the Aerona Smart Controller touchscreen instead of the external isolator (installer procedure).

What you can check

  • Note the exact code shown on the controller display and tell your installer or Grant-trained engineer.
  • Check the heating system pressure gauge (if one is fitted) and report a low reading to your installer; make sure the filling loop valves are closed.

What the engineer will check

  • Check operation of water pump; replace if faulty.
  • Check system water pressure, blockage (filter) or closed valves; refill, clean filter, open valves.
  • Check connections between water pump and hydraulic PCB.
  • Check the hydraulic PCB; replace if faulty.

Who to ask for: Grant-trained heat pump engineer.