P05Grant · Aerona 290

P05 on a Grant Aerona 290: Discharge temperature protection

Short answer

On a Grant heat pump, P05 means: Discharge temperature protection. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Discharge temperature protection.

Part involved: compressor discharge / TP sensor.

Likely causes:

  • Lack of refrigerant.
  • Discharge temperature sensor is faulty.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in DOC 0204.

Manual reset: DOC 0204 s11.1: once the fault is resolved, reset by turning the unit OFF and back ON; s11.5: power cycle can be done from the Aerona Smart Controller touchscreen instead of the external isolator (installer procedure).

What you can check

  • Note the exact code shown on the controller display and tell your installer or Grant-trained engineer.
  • Check the heat pump isolator switch and the consumer-unit breaker/RCD for the heat pump are ON (do not repeatedly reset a tripping breaker).

What the engineer will check

  • Check for leak in refrigerant circuit; repair the leak.
  • Check discharge temperature sensor (TP); replace if faulty.

Who to ask for: Grant-trained heat pump engineer.

Certification: F-gas certified engineer also trained/competent for flammable A3 refrigerant R290 (propane).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.