L7 on a Grant heat pump: Mixing valve error

Short answer

On a Grant heat pump, L7 means: Mixing valve error. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manual says: Mixing valve error.

Part involved: mixing valve / terminal PCB.

Likely causes:

  • Clogged water pump and/or water circuit.
  • PCB(Terminal) faulty.
  • Mixing valve faulty.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: No.

Manual reset: Engineer: press - and + on the master remote controller for 3 s, or Reset SW on PCB(Terminal).

What you can check

  • Note the exact code shown on the controller display and tell your installer or Grant-trained engineer.
  • Grant advises homeowners NOT to reset Aerona3 fault codes themselves - leave the reset to the engineer.
  • Check the heating system pressure gauge (if one is fitted) and report a low reading to your installer; make sure the filling loop valves are closed.

What the engineer will check

  • Check the pump and water circuit; remove obstructions, clean filter.
  • Check terminal PCB voltage by tester; replace if faulty.
  • Otherwise replace mixing valve.

Who to ask for: Grant-trained heat pump engineer.

What you might notice

What owners and engineers report

18 owner and engineer reports mention this.

  • Insufficient heating (house not warm enough) on the Aerona³ R32: 17 reports
  • Underfloor heating problem on the Aerona³ R32: 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.